Provide various types of flow meters, electromagnetic flow meters, superior performance, integrity business, rest assured choice! All kinds of meter flowmeter, full variety of excellent prices, reliable quality and long life, welcome to buy! Electromagnetic flowmeter | Guangzhou electromagnetic flowmeter | Guangdong flow meter | flowmeter manufacturers quote | Guangzhou flowmeter manufacturers | Supply - Guangzhou Dichuan Instrument Co., Ltd. hotline: 020-85628522 85550363 Electromagnetic flowmeter applications : pulp flow measurement, juice flow measurement, dirty process fluid measurement , micro flow measurement, cold water flow measurement. Oily wastewater measurement, hot water flow measurement, household heat measurement , building heat measurement, water meter measurement, pump efficiency test, process flow measurement, open channel flow measurement. Demineralized Water Flow Measurement, Large Diameter Sewage Measurement, Power Plant Cooling Water Measurement, Non-full Tube Flow Measurement, Corrosive Flow Measurement, Untreated Sewage Measurement, Tap Water Flow Measurement, High Pressure Natural Gas Metering, Factory Emission Liquid Metering, Non-Contact Flow Measurement . Pump water flow measurement Features :
CNC Turning is namely Lathe machining, Lathe machining is a portion of mechanical processing.
Lathe machining is always a process that turning tools doing turning machining to a rotary workpiece. On CNC lathes, the operators or the engineers also can use drills, reamers, screw taps, threading dies and knurling tools to make relative machining work. CNC turning is usually applied to machining shafts, plates, bushings and all other workpieces which have rotary surfaces, it is a very widely application in practical mechanical manufacturing.
CNC turning can be divided into rough turning and finish turning, rough turning is for the purpose of machining with big cutting depth and big feed rate, to improve the machining efficiency. However, the precision of rough turning can only be grade IT11, the surface finish can only be Ra 20-10um. On the contrary, semi-finish machining and finish machining usually can only apply high speed but small feeding rate and cutting depth. In this condition, the machining accuracy can be up to grade IT10-7, the roughness can be Ra10-0.6um.
Cnc Turning,Cnc Machining Parts,Die Casting,Aluminum Castings,Malaysia Aluminum Die Casting,Malaysia Aluminum Parts NINGBO ZHENHAI BOLANG METAL PRODUCT FACTORY , https://www.diecastingdie.com
About electromagnetic flow meter: electromagnetic flowmeter is the 1960s with the development of electronic technology and the rapid development of new flow measurement instruments. Electromagnetic flowmeters are made according to Faraday's magnetic induction law and are used to measure the volume flow of conductive liquids. Due to its unique advantages, it has been widely used in the measurement of various conductive liquids in industry. For example, measuring various acids, alkalis, salts and other corrosive liquids; various flammable and explosive media; various industrial sewage, pulp, sediment, etc.
1. The electromagnetic flowmeter has a simple and reliable structure, no moving parts, and long working life.
2. No blocking flow blocking parts, no pressure loss and fluid blocking.
3. No mechanical inertia, fast response, good stability, can be applied to automatic detection, adjustment and program control system.
4 has a pipeline, plug-in type easy to install.
5. With integrated and split type for easy selection.
6. The measurement accuracy is not affected by the type of medium to be measured and the physical parameters such as temperature, viscosity, density, and pressure.
7. The use of different combinations of PTFE or rubber lining and Hc , Hb , 316L , Ti and other electrode materials can meet the needs of different media.
8. Using EEPROM memory, measurement and data storage protection is safe and reliable.
9. Various signal transmission methods and power supply methods.
10. High-resolution LCD backlight display.
Technical Parameters:
Instrument accuracy: Pipeline 0.5 , 1.0 ; plug-in level 1.5
Measurement media: Various liquid and liquid-solid two-phase fluids with electrical conductivity greater than 5 μS/cm .
Flow rate range: 0.01 ~ 15m/s
Working pressure: 1.6MPa
Ambient temperature: -40°C to +50°C
Medium temperature: Teflon lining ≤180°C
Rubber lining: ≤65°C
Explosion-proof mark: ExmibdIIBT4
Explosion-proof license number: GYB01349
External magnetic interference: ≤400A/m
Shell protection: Integrated type: IP65 ;
Separate type: Sensor IP68 ( 5 meters underwater, rubber lining only ) Converter IP65
Output signal: 4 to 20mA.DC , load resistance 0 to 750Ω
Communication output: RS485 or CAN bus
Electrical connection: M20×1.5 female thread, φ10 cable hole
Supply voltage: 90 to 220VAC , 24±10%V.DC
High power consumption: ≤10VA