Nylon Conveyor Belt,Conveyor Belt,Nn Conveyor Belt Heat Resistant Conveyor Belt Steel Cord Conveyor Belt Co., Ltd. , http://www.nsepconveyorbelt.com
GD2134D Cable Identifier includes a transmitter and a receiver, it can be used to locate trace and depth of the underground cables and metallic pipes, also to identify the cable from a bunch of cables.
Features
Â
Transmitter
Â
Output (Three mode): Direct connection output, Clamp Coupling output, Radiation induction.
Frequency (6 for choice): 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, including 500Hz and 1kHz is complex frequency. It can realize the function of Correct/False indication and pipe identification with the help of Receiver.
Fault signal output to detect Pipe grounding fault.
Power output: Max. 10W, 4 steps adjustable.
Automatic impedance matching and functions of overload&short-circuit protection.
Power supply: Internal rechargeable Lithium battery. It can be recharged by charger (AC 220V) or car cigarette lighter (12V).
If low battery, the instrument will shut down automatically, to protect battery.
Robust and portable.
Â
Receiver
Â
Left/Right arrow indication for Cable Route Tracing. (Patent technology)
Correct/False indication (Patent technology). It will point to the forward when the detected cable is traced correctly. Otherwise, it will point to the backward and it will show "?".
Strong anti-interference.
Automatic measurement of depth and current.
Various detection mode, more accurate.
Detection frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, suitable for different conditions.
Two passive detection frequency bands: power frequency and radio frequency (RF). No need to connect with audio frequency generator.
History curve display.
Cable identification: Clamp identification and stethoscope identification. Clamp identification can measure the current amplitude and direction of cable precisely and give accurate result. Stethoscope identification is a traditional method when it is not convenient to use Clamp identification. It is easy wiring for Stethoscope identification.
Grounding fault location.
Built-in Rechargeable lithium battery.
Automatic shut down if there is no operation in 30mins.
Robust and portable.
Â
Â
Specifications
Â
Transmitter
Â
Output frequency
500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz. 500Hz and 1kHz are complex frequency. 8Hz is very low complex frequency. It is the frequency of fault location.
Output power
Max.10W for 500Hz, 1kHz, 8kHz, 33kHz and fault location. frequency. Four steps adjustable: 2.5W, 5W, 7.5W, 10W. 1W for 66kHz and 93kHz.
Output voltage
Max.200V (AC peak value), automatic adjustable according to the load.
Display
128*64 LCD display.
Built-in Lithium battery
Nominal 14.8V, 7Ah.
External power supply
Rated voltage DC12V (car cigarette lighter output)
Charger
AC 100-240V input, 50/60Hz, output DC 16.8V,2A/3A.
Size
275*220*100mm
Weight
2.4kg
Working condition
Temperature -10--40ºC
Humidity 5-90% RH
Altitude<4500m
Â
Receiver
Input mode: Built-in receiving coil, Clamp, 1k Stethoscope, 8k Stethoscope, A type fault detection device.
Receiving frequency:
Active Detection Frequency For Pipes: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz And 93kHz.
Passive detection frequency: Power frequency and radio frequency (RF).
Clamp identification frequency: 500Hz, 1kHz complex frequency.
Clamp current measurement frequency: 500Hz, 1kHz, 8kHz.
Stethoscope identification frequency: 1kHz, 8kHz..
Grounding fault location frequency: 8Hz complex frequency.
Pipe detection mode:
Â
Automatic Peak Method (Wide): It Is Suitable For Active Detection, With Left/Right Direction Indication. When The Frequency Is 500Hz And 1kHz, There Is Correct/False Indication.
Peak method: suitable for passive detection.
Narrow method
Null method
Cable identification mode:
Automatic Clamp identification
Clamp current measurement
Stethoscope identification
320*240 LCD display, shows signal amplitude, left/right direction, correct/false indication, history curve of signal strength, depth, current and result.
Built-in Lithium battery, rated 7.4V, 7Ah.
Charger: AC100-240V input, 50/60Hz, output DC 8.4V,2A/3A.
Size: 700*270*120mm
Weight: 3.5kg
Working condition: Temperature 0-40ºC, Humidity 5-90% RH, altitude<4500m.
Â
GD2134D Cable Identifier includes a transmitter and a receiver, it can be used to locate trace and depth of the underground cables and metallic pipes, also to identify the cable from a bunch of cables.
Features
Â
Transmitter
Â
Output (Three mode): Direct connection output, Clamp Coupling output, Radiation induction.
Frequency (6 for choice): 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, including 500Hz and 1kHz is complex frequency. It can realize the function of Correct/False indication and pipe identification with the help of Receiver.
Fault signal output to detect Pipe grounding fault.
Power output: Max. 10W, 4 steps adjustable.
Automatic impedance matching and functions of overload&short-circuit protection.
Power supply: Internal rechargeable Lithium battery. It can be recharged by charger (AC 220V) or car cigarette lighter (12V).
If low battery, the instrument will shut down automatically, to protect battery.
Robust and portable.
Â
Receiver
Â
Left/Right arrow indication for Cable Route Tracing. (Patent technology)
Correct/False indication (Patent technology). It will point to the forward when the detected cable is traced correctly. Otherwise, it will point to the backward and it will show "?".
Strong anti-interference.
Automatic measurement of depth and current.
Various detection mode, more accurate.
Detection frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, 93kHz, suitable for different conditions.
Two passive detection frequency bands: power frequency and radio frequency (RF). No need to connect with audio frequency generator.
History curve display.
Cable identification: Clamp identification and stethoscope identification. Clamp identification can measure the current amplitude and direction of cable precisely and give accurate result. Stethoscope identification is a traditional method when it is not convenient to use Clamp identification. It is easy wiring for Stethoscope identification.
Grounding fault location.
Built-in Rechargeable lithium battery.
Automatic shut down if there is no operation in 30mins.
Robust and portable.
Â
Â
Specifications
Â
Transmitter
Â
Output frequency
500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz. 500Hz and 1kHz are complex frequency. 8Hz is very low complex frequency. It is the frequency of fault location.
Output power
Max.10W for 500Hz, 1kHz, 8kHz, 33kHz and fault location. frequency. Four steps adjustable: 2.5W, 5W, 7.5W, 10W. 1W for 66kHz and 93kHz.
Output voltage
Max.200V (AC peak value), automatic adjustable according to the load.
Display
128*64 LCD display.
Built-in Lithium battery
Nominal 14.8V, 7Ah.
External power supply
Rated voltage DC12V (car cigarette lighter output)
Charger
AC 100-240V input, 50/60Hz, output DC 16.8V,2A/3A.
Size
275*220*100mm
Weight
2.4kg
Working condition
Temperature -10--40ºC
Humidity 5-90% RH
Altitude<4500m
Â
Receiver
Input mode: Built-in receiving coil, Clamp, 1k Stethoscope, 8k Stethoscope, A type fault detection device.
Receiving frequency:
Active Detection Frequency For Pipes: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz And 93kHz.
Passive detection frequency: Power frequency and radio frequency (RF).
Clamp identification frequency: 500Hz, 1kHz complex frequency.
Clamp current measurement frequency: 500Hz, 1kHz, 8kHz.
Stethoscope identification frequency: 1kHz, 8kHz..
Grounding fault location frequency: 8Hz complex frequency.
Pipe detection mode:
Â
Automatic Peak Method (Wide): It Is Suitable For Active Detection, With Left/Right Direction Indication. When The Frequency Is 500Hz And 1kHz, There Is Correct/False Indication.
Peak method: suitable for passive detection.
Narrow method
Null method
Cable identification mode:
Automatic Clamp identification
Clamp current measurement
Stethoscope identification
320*240 LCD display, shows signal amplitude, left/right direction, correct/false indication, history curve of signal strength, depth, current and result.
Built-in Lithium battery, rated 7.4V, 7Ah.
Charger: AC100-240V input, 50/60Hz, output DC 8.4V,2A/3A.
Size: 700*270*120mm
Weight: 3.5kg
Working condition: Temperature 0-40ºC, Humidity 5-90% RH, altitude<4500m.
Â
Cable Identifier and tracing tester
Model NO.: GD-2134D
Customized: Non-Customized
Color: Blue
Output Frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz
Output Power: Max.10W
Output Voltage: Max.200V (AC Peak Value)
Display: 128*64 LCD Display
Built-in Lithium Battery: Nominal 14.8V, 7ah
External Power Supply: Rated Voltage DC12V (Car Cigarette Lighter Output
Charger: AC 100-240V Input, 50/60Hz, Output DC 16.8V, 2A/3A
Trademark: HV Hipot
Transport Package: Wooden Case
Specification: ISO, SGS
Origin: China
HS Code: 9030332000
Model NO.: GD-2134D
Customized: Non-Customized
Color: Blue
Output Frequency: 500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz
Output Power: Max.10W
Output Voltage: Max.200V (AC Peak Value)
Display: 128*64 LCD Display
Built-in Lithium Battery: Nominal 14.8V, 7ah
External Power Supply: Rated Voltage DC12V (Car Cigarette Lighter Output
Charger: AC 100-240V Input, 50/60Hz, Output DC 16.8V, 2A/3A
Trademark: HV Hipot
Transport Package: Wooden Case
Specification: ISO, SGS
Origin: China
HS Code: 9030332000